CO2, Temp & RH Monitor (CO2M) 230V

CO2, Temp & RH Monitor (CO2M) 230V

The Flamefast Carbon Dioxide,Temperature and Relative Humidity Monitor provides a bold visual indication using a traffic light backlit LCD, as well as having a digital readout to displays the levels/concentrations.

Using the built-in Volt Free Contact, the unit can be easily interfaced with Ventilation and Window Control Systems, as we as Gas Safety Systems. The unit can also simply be used as a traffic light indication to raise awareness of CO2, Temp or RH levels.

The unit offers four user selectable programmes for different applications; two aimed at Ventilation and a further two aimed at Gas Safety. Custom software profiles are also available to control the audible alarm, the relay set point and the traffic light changeover levels, based on any combination of CO2, Temp & RH (CO2 default).

Downloads

View FileCO2 Temp & RH Monitor (CO2M)

Key Features

  • 100 - 240VAC Power Supply
  • Clear digital readout
  • Bold traffic light indication
  • Volt free contact output
  • Typical 10+ Year life expectancy
  • Self-Calibrating CO2 & Sensor
  • Audible Alarm
  • Mounts onto any standard single gang junction box or conduit box
  • UK MANUFACTURED

Technical Specification

Power Supply 100-240VAC 50/60Hz
Power Consumption 3W Max
CO2 Range 0 - 5,000ppm
CO2 Accuracy ±40ppm +3% @NTP
CO2 Display Resolution 1ppm
CO2 Sensing Method Solid State NDIR
CO2 Typical Sensor Life 10+ Years
Temp Range 0 - 50°C
Temp Accuracy ±0.5°C @ 25°C
Temp Display Resolution 0.1°C
RH Range 0 - 100%
RH Accuracy 2% @ 20 - 80%
RH Display Resolution 0.1%
VFC Output Rating SPST - 5A @ 240V Max
Operating Conditions Temp 0 - 50°C
Humidity 0 - 95% (NC)
Sampling Method Diffusion
Warm-up Time 30 seconds
IP Rating IP40
Housing Material Flame Retardant ABS
Colour Pure White (RAL9010)
Approval CE

Dimensions

Height 125 mm
Width 86 mm
Depth 36 mm

Installer Selectable Options

  • Audible Alarm (Enable/Disable)
  • Backlight (Enable/Disable)
  • Replace PPM reading with 'CO2@ on display
  • Traffic light changeover levels and Volt Free Contact activation

The CO2M has four factory set user selectable programmes to control the Volt Free Contact and LCD Traffic Light behaviour.

These are as follows:

Program 1 2 3 4
Green - Yellow 1,000 1,000 1,500 1,500
Yellow - Red 1,500 1,500 2,800 2,800
Relay Position N/O N/O N/C N/C
Relay Set Point 1,000 1,500 2,800 4,500

Part Numbers & Options / Accessories

Part No Description
CO2M CO2 & Temp Monitor