BoilerGuard

The New BoilerGuard system provides a complete and comprehensive gas safety system for boiler plant room applications, providing a central interface for all common safety interlocks, including Fire Alarm Systems, Thermal Fusible Links, and Gas Sensors.

Top Key Features

  • New Stylish Enclosure
  • Proving or Non-proving selectable
  • Auto-reset following Fire Alarm
  • Auto-reset following Power Failure
  • Optional BACnet/Modbus module
  • 24VDC auxiliary power output
  • UK Manufactured...

Overview

The New BoilerGuard system provides a complete and comprehensive gas safety system for boiler plant room applications, providing a central interface for all common safety interlocks, including Fire Alarm Systems, Thermal Fusible Links, and Gas Sensors.

With numerous hardware and firmware upgrades, the BoilerGuard can now monitor up to 24 Flamefast Gas Sensors, with simple menus to navigate through and view the sensor information, and the upgraded power supply can power between 10 and 24 sensors (depending on sensor type).

The BoilerGuard’s unrivalled flexibility makes it one of the most versatile, yet cost-effective safety systems available, with the relay outputs and optional BACnet/Modbus interface module allowing simple integration into most third-party systems.

Key Features

  • New Stylish Enclosure
  • Proving or Non-proving selectable
  • Auto-reset following Fire Alarm
  • Auto-reset following Power Failure
  • Optional BACnet/Modbus module
  • 24VDC auxiliary power output
  • Interfaces for:
    - Thermal Links
    - Ventilation Systems
    - Remote Emergency Stop Buttons
    - Fire Alarm Systems
  • Remote reset interface
  • Relays for Alarm 1, Alarm 2, and Fault
  • 5 Year Warranty
  • UK MANUFACTURED

Dimensions

Height:180 mm
Width:180 mm
Depth:60 mm
70 mm including Stop Button

Technical Specifications

Power Supply:85 ~ 300VAC 50/60Hz
Power Consumption:20W Max (Panel Only)
Power Output:
Gas Solenoid: Switched Mains (5A Fused)
Alarm 1: SPDT - 5A @ 250V Max
Alarm 2: SPDT - 5A @ 250V Max
Fault: SPST - 5A @ 250V Max
BACnet MS/TP or Modbus RTU (with -COM)
Operation Conditions:
Temp: 0 ~ 50°C
Humidity: 0 ~ 95% (NC)
Body Material:PC/ABS
IP Rating:IP65
Colour:Dark Grey
Approval:CE, UKCA

External Device Interfaces

Pressure TransmitterPT00 Connection
24V Out24V DC Power Out - 600mA (for TR, SS, FGS)
Gas SensorBACnet Interface for FGS Range
VentilationLV Signal to monitor external VFC
Thermal LinkLV Signal to monitor external VFC
Fire AlarmLV Signal to monitor external VFC
Remote StopLV Signal to monitor external VFC
Remote ResetLV Signal to monitor Momentary Switch

Installer Selectable Options

Gas Pressure ProvingON / OFF
Gas Proving Fill/Test Time5s Fill + 30s Test / 10s Fill + 60s Test
Fire Alarm Auto-resetON / OFF
Power Failure Auto-resetON / OFF

NEED THE REQUIREMENTS?

minReq-Kitchen

Commercial
Kitchens

arrow-kitchen
minReq-lab

Teaching
Areas

arrow-lab
minReq-plant

Plant 
Rooms

arrow-plant

Part Numbers & Options / Accessories

PART NODESCRIPTION
BG-P0BoilerGuard Panel (Non-proving)
BG-PT00-COMBoilerGuard c/w Pressure Transmitter (Proving) +BACnet/Modbus Communication Module
  
FGS-NGFlamefast Gas Detector - Natural Gas
FGS-LPGFlamefast Gas Detector - Propane
FGD-COFlamefast Gas Detector - Cabon Monoxide
TFLThermal Fusible Link (70°C) - Auto-reset
RSTOPRemote Emergency Stop - Twist Release
AVT24BTraffic Light Alarm Indicator - Black
CABLE1Belden 8723 Equivalent (100m)

Data Sheets

General specifications in .pdf format

BIM Files

CAD drawings in .rfa format